Welcome to Shenzhen Hong Jia Wei Technology Co., Ltd. official website!
Hot key:Schneider servo PLC touch screen maintenance  Lenz servo PLC touch screenSchneider  Lenz  Beyford  Siemens  AB  Xinjie server PLC touch screen maintenance  


Shenzhen Hong Jia Wei Technology Co., Ltd.
Add: 303, floor 3, No. 296, Xinsheng Road, Longgang street, Longgang District, Shenzhen
Phone: 0755-28916839
Technology:13640994287
Complaints Hotline:13316842705
LUST maintenance
You are here:Home >> servo repair >> LUST maintenanc...
Roest servo motor maintenance
Model:  
Category:   LUST maintenance
Roest servo motor maintenance - Hong Jia Wei professional roest servo motor maintenance phase, overcurrent, overvoltage, undervoltage, overheating, overload, encoder fault, coil burnout, bearing failure, parameter error, output module, display without damage, please call the service hotline 0755-28916839, 13640994287, we have professional customer service staff to quickly respond to your needs.
Description Parameter
Roest servo motor maintenance
Model: LSM108-100-2F
Failure phenomenon: boot failure
Fault analysis: the customer said the motor in the power on reported encoder fault, according to the customer that open motor cover no obvious burnt traces found that whether there is short circuit of motor encoder static measurement of voltage power supply 5V, found no short-circuit phenomenon, the encoder power measurement output waveform 485 communication pulse waveform is not normal, according to the line check the 485EX patch has been bad for its replacement and normal waveform measurement. On the machine runs everything is normal.
Fault repair: replace IC485EX.
Hong Jia Wei professional roest servo motor maintenance phase, overcurrent, overvoltage, undervoltage, overheating, overload, encoder fault, coil burnout, bearing failure, parameter error, output module, display without damage
Jia Hong Wei repair service hotline: 0755-28916839, 13640994287 Shaw
Roest servo motor maintenance - Hong Jia Wei professional roest servo motor maintenance phase, overcurrent, overvoltage, undervoltage, overheating, overload, encoder fault, coil burnout, bearing failure, parameter error, output module, display without damage, please call the service hotline 0755-28916839, 13640994287, we have professional customer service staff to quickly respond to your needs.